• Furon® UPX 2000 Diaphragm Valve Manually Actuated, 3-Way Multi Turn

    Applications

    • Designed for use in the Semiconductor industry for transfer of highly aggressive ultrapure chemicals including concentrated hydrochloric acid (HCl) and de-ionized water
    • UPX 2000 series valve is ideal for applications that demand high-pressure capabilities and a high Cv flow factor
    • Provide a convenient way of mixing compatible fluids that do not have strict mixing ratio requirements
    Operation
    • Manually operated diverting/mixing valve
    • Designed to handle up to 100 PSIG (690 kPa) forward pressure
    Notes
    When selecting Flare Grip®II ends, we recommend end connections that are larger than the valve orifice size in order to achieve full flow.
    This product is class 100 clean room assembled and double bagged. Leak detection port on side has standard port size of 1/4-28.

  • Furon® UPX 2000 Diaphragm Valve Manually Actuated, 2-Way Multi-Turn

    Applications

    • Designed for primary use in the Semiconductor industry for transfer of highly aggressive ultrapure chemicals including concentrated hydrochloric acid (HCl) and de-ionized water
    • UPX 2000 series valve is ideal for applications that demand high-pressure capabilities and a high Cv flow factor
    • Performs throttling functions to reduce flow rates upstream from sensitive devices such as filters
    • Volumetric control in process tank overflow and refresh rates
    • Performs approximate metering functions
    Operation
    • Manually operated multi-turn valve
    • Designed to handle up to 100 PSIG (690 kPa) pressure
    Notes
    When selecting Flare Grip®II ends, we recommend end connections that are larger than the valve orifice size in order to achieve full flow.
    This product is class 100 clean room assembled and double bagged. Leak detection port on side has standard port size of 1/4-28.

  • Furon® UPX 2000 Diaphragm Valve Pneumatically Actuated, 2-Way

    Applications

    • Designed for primary use in the Semiconductor industry for transfer of highly aggressive ultrapure chemicals including concentrated hydrochloric acid (HCl) and de-ionized water
    • UPX 2000 series valve is ideal for applications that demand high-pressure capabilities and a high Cv flow factor
    • Distribution and point of use shutoff
    Operation
    • Pneumatically actuated on/off valve using air pressure
    • Designed to handle up to 100 PSIG (690 kPa) pressure
    Notes
    When selecting either Flare Grip™, Flare Grip®II or Grab Seal™ ends, we recommend end connections that are larger than the valve orifice size in order to achieve full flow.
    This product is class 100 clean room assembled and double bagged. Pneumatic Air Port on top of valve has standard 1/8" (3.18mm) FNPT port. Leak detection port on side has standard port size of 1/4-28.

  • Furon® UPX 2000 Diaphragm Valve Manually Actuated, 2-Way 1/4 Turn

    Applications

    • Designed for primary use in the Semiconductor industry for transfer of highly aggressive chemicals including hydrochloric acid (HCI) and hydrofluoric acid (HF) to ultra-pure de-ionized water
    • UPX 2000 series valve is ideal for applications that demand high-pressure capabilities and a high Cv flow factor
    • Ideal as master isolation and point-of-use system isolation
    Operation
    • Manually operated on/off valve
    • Designed to handle up to 100 PSIG (690 kPa) pressure
    Notes
    When selecting Flare Grip®II ends, we recommend end connections that are larger than the valve orifice size in order to achieve full flow.
    This product is class 100 clean room assembled and double bagged. Leak detection port on side has standard port size of 1/4-28.

  • Furon® UPX 2000 Diaphragm Valve Pneumatically Actuated, 3-Way

    Applications

    • Designed for primary use in the Semiconductor industry for transfer of highly aggressive ultrapure chemicals including concentrated hydrochloric acid (HCl) and de-ionized water
    • UPX 2000 series valve is ideal for applications that demand high-pressure capabilities and a high Cv flow factor
    • Ideal for diverting media flow path
    Operation
    • Pneumatically actuated 3 way valve allows for common input and alternating output
    • Engineered to operate up to 100 PSIG (690 kPa) forward pressure
    Notes
    When selecting either Flare Grip™, Flare Grip®II or Grab Seal™ ends, we recommend end connections that are larger than the valve orifice size in order to achieve full flow.
    This product is class 100 clean room assembled and double bagged. Pneumatic Air Port on top of valve has standard 1/8" (3.18mm) FNPT port. Leak detection port on side has standard port size of 1/4-28.

  • Furon® UPX 2000 Diaphragm Valve Pneumatically Actuated, 2-Way

    Applications

    • Designed for primary use in the Semiconductor industry for transfer of highly aggressive ultrapure

  • Furon® UPX 2000 Diaphragm Valve Pneumatically Actuated, 2-Way

    Applications

    • Designed for primary use in the Semiconductor industry for transfer of highly aggressive ultrapure chemicals including concentrated hydrochloric acid (HCl) and de-ionized water
    • UPX 2000 series valve is ideal for applications that demand high-pressure capabilities and a high Cv flow factor
    • Distribution and point of use shutoff
    Operation
    • Pneumatically actuated on/off valve using air pressure
    • Designed to handle up to 100 PSIG (690 kPa) pressure
    Notes
    When selecting either Flare Grip™, Flare Grip®II or Grab Seal™ ends, we recommend end connections that are larger than the valve orifice size in order to achieve full flow.
    This product is class 100 clean room assembled and double bagged. Pneumatic Air Port on top of valve has standard 1/8" (3.18mm) FNPT port. Leak detection port on side has standard port size of 1/4-28.

  • Furon® UPX 2000 Diaphragm Valve Pneumatically Actuated, 2-Way

    Applications

    • Designed for primary use in the Semiconductor industry for transfer of highly aggressive ultrapure chemicals including concentrated hydrochloric acid (HCl) and de-ionized water
    • UPX 2000 series valve is ideal for applications that demand high-pressure capabilities and a high Cv flow factor
    • Distribution and point of use shutoff
    Operation
    • Pneumatically actuated on/off valve using air pressure
    • Designed to handle up to 100 PSIG (690 kPa) pressure
    Notes
    When selecting either Flare Grip™, Flare Grip®II or Grab Seal™ ends, we recommend end connections that are larger than the valve orifice size in order to achieve full flow.
    This product is class 100 clean room assembled and double bagged. Pneumatic Air Port on top of valve has standard 1/8" (3.18mm) FNPT port. Leak detection port on side has standard port size of 1/4-28.

  • Furon® UPX 2000 Diaphragm Valve Pneumatically Actuated, 2-Way

    Applications

    • Designed for primary use in the Semiconductor industry for transfer of highly aggressive ultrapure chemicals including concentrated hydrochloric acid (HCl) and de-ionized water
    • UPX 2000 series valve is ideal for applications that demand high-pressure capabilities and a high Cv flow factor
    • Distribution and point of use shutoff
    Operation
    • Pneumatically actuated on/off valve using air pressure
    • Designed to handle up to 100 PSIG (690 kPa) pressure
    Notes
    When selecting either Flare Grip™, Flare Grip®II or Grab Seal™ ends, we recommend end connections that are larger than the valve orifice size in order to achieve full flow.
    This product is class 100 clean room assembled and double bagged. Pneumatic Air Port on top of valve has standard 1/8" (3.18mm) FNPT port. Leak detection port on side has standard port size of 1/4-28.